Release Notes: CODESYS PROFINET 4.5.0.0

Key Issue Type Summary Resolution Note
PN-665 Improvement

GSDML Converter: Update safety-related documents for Tool Classification

Fixed
PN-641 Bug

Profinet Controller (IEC): Connections Do Not Recover

Fixed
PN-639 Bug

Profinet Controller (CIFX V3): RDREC / WRREC Show Invalid Error Codes

Fixed
PN-635 Bug

Profinet (IEC) - RPC: NoCall - Reject Invalid

Fixed
PN-626 Improvement

SafetyGSDMLConverter: Use LongPath-Utilities when creating files

Fixed
PN-622 Bug

Profinet / RPC: Cycle Time of CommTask on RTE

Fixed
PN-619 Improvement

Profinet Controller (CIFX V3): IO-Link Licence Check Message

Fixed
PN-611 Bug

Profinet Controller (CIFX V3): Check Limit of DPM Data faulty

Fixed
PN-608 Bug

Profinet Device (IEC): DeviceAR FB Shows Invalid Abort Code

Fixed
PN-606 Bug

Profinet Controller (IEC): Corrupted PROFIsafe IO-Mapping

Fixed
PN-600 Bug

Profinet (IEC): MRP Client sends invalid MRP Domain UUID

Fixed
PN-599 Improvement

Improve information/message that the driver resets the network settings

Won't Fix [[GENERAL]]
Das Verhalten ist so gewünscht und erforderlich.
On eine Datei mit remanenten Daten vorhanden ist oder nicht spielt keine Rolle. In den remanenten Daten könnte auch die IP=0.0.0.0 stehen oder aber das "use temporary" flag, was wiederum bedeutet, daß das Gerät ohne Ip startet (gleiches gilt für den Sationsnamen).
PN-598 Bug

Profinet Controller: ProfiSafeHost communication does not work any more

Won't Fix [[GENERAL]]
Changes to Safety Solution require PN 4.5.0.0.
PN-597 Bug

Profinet Controller: Reading Value of Record-Data Parameter Fails

Fixed
PN-595 Bug

Profinet Controller (IEC): MRP Client sends no Topology Change

Fixed
PN-589 Bug

Profinet Device (IEC): Legacy MRP-Configuration is Invalid

Fixed
PN-587 Epic

Profinet/Profisafe: Support TCI

Fixed [[KNOWN_LIMITATIONS]]
PN-640
PN-581 Improvement

Profinet Configurator / TCI: Device Tool Invocation

Fixed
PN-580 Bug

Profinet Device (IEC): Topology Detection of non-PROFINET Switches

Fixed
PN-579 Bug

Profinet Configurator: GSDML Import and DataType 'Date' / 'BinaryDate'

Fixed
PN-578 Improvement

Profinet Controller: TCI Service Handler

Fixed
PN-577 Improvement

Profinet Import: Support of Profisafe V2.6 GSDML files

Fixed
PN-576 Bug

Profinet Device: DeviceAR FB may block Connection

Fixed
PN-574 Improvement

Profinet Configurator: GSDML Import shall create Icon from Bmp

Fixed
PN-572 Improvement

Profinet Device (IEC): Programatic Config lacks Option for MRP

Fixed
PN-564 Bug

Profinet Configurator / Scan-Dialog: Gateway not Set

Fixed
PN-545 Improvement

Change Vendor to CODESYS

Fixed
PN-539 Bug

Profinet Configurator: MRP Configurator and Special Characters

Fixed
PN-527 Improvement

PN Device/Module: Generate Text List from GSDML

Duplicate [[GENERAL]]
duplicates PN-124
PN-524 Improvement

Profinet (IEC) / RTE: Enable 1GBit support in LLDP

Fixed
PN-428 Improvement

Profinet Configurator: Upgrade GSDML Schema

Fixed