Release Notes: CODESYS V3.5 SP20 Patch 3

Key Issue Type Summary Resolution Note
CDS-90934 Bug

CLONE - CmpCodeMeter: Disconnect and connect a CmRuntime does not reconnect licenses

Cannot Reproduce [[GENERAL]]
Issue cannot be reproduced.
CDS-90918 Bug

CLONE - M4 Export - Order of typedefs in M4 file is unstable for interface sub-elements

Fixed
CDS-90916 Bug

CLONE - PLCopenXML with AddDataProvider can't export explicit connector types

Fixed
CDS-90896 Bug

CLONE - Update Compiler Version: wrong order of execution

Fixed
CDS-90874 Bug

CLONE - Compile: Internal error 2 during OnlineChange

Fixed [[GENERAL]]
Fixed for CompilerVersion >= 3.5.20.30
CDS-90872 Bug

CLONE - Precompile error - data type conversion

Fixed [[GENERAL]]
Compilerversion >= 3.5.20.30
CDS-90871 Bug

CLONE - IntelliSense not working at Conversion Function

Won't Fix [[GENERAL]]
An open regression prevents the patch integration.
CDS-90783 Improvement

CLONE - CmpCodeMeter: Online Service to transport UsagePeriod, ExpirationTime and MaintenancePeriod of licenses

Fixed
CDS-90742 Bug

CLONE - Security issues in CodeMeter versions before 8.10a

Won't Fix [[GENERAL]]
Due to an bug in version 8.10a of the CodeMeter runtime, the update will not be carried out.
CDS-90735 Bug

CLONE - [Dev+Test] Transition Object: erroneuos code for SFC analyzation

Fixed
CDS-90734 Bug

CLONE - Project Compare: Clicking Backspace leads to exception

Fixed
CDS-90732 Improvement

CLONE - PROFIsafe: Interface for Data Exchange

Fixed
CDS-90710 Improvement

CLONE - SysSocketLinux: replace select with poll

Fixed [[GENERAL]]

On Linux select is limited to less than 1024 file descriptors.
Because of that we added the Option to use poll() for SysSocketSelect which does not have these limitations.

Per default select() will be used.

There is a new setting to switch to the new Implementation using poll():

/**
* <category>Settings</category>
* <type>Int</type>
* <description>
* You can specify whether select() or poll() should be used for SysSocketSelect. On Linux select is limited to less than 1024 file descriptors.
* 0: Use poll()
* 1(DEFAULT): Use select()
* </description>
*/
CDS-90636 Bug

CLONE - Gateway SysTray: Config mode cannot be activated - hint for manual activation necessary

Fixed
CDS-90613 Bug

CLONE - Compiler: Changed initial values of VAR_Inst are not updated on Download

Fixed [[GENERAL]]
Compilerversion >= 3.5.20.30
CDS-90607 Bug

CLONE - SysTaskVxWorks.c : Add NULL pointer check

Fixed
CDS-90606 Bug

CLONE - Generate Code: Generate Code leads to freeze for project with specific ST POU with 6700 lines of code

Fixed
CDS-90605 Improvement

CLONE - ComponentManager: Probe for latest GAC version if exact is missing

Won't Fix [[GENERAL]]
After investigation, the problem which led to this clone-issue is not associated with the component manager. Therefore, this a clone-issue is not required any more.
CDS-90604 Bug

CLONE - Non-escaped characters in description field causes import/export of csv to fail

Fixed
CDS-90558 Improvement

CLONE - [Object Manager] Report unconsolidated changes to the project format

Fixed [[GENERAL]]
IProjectFormat2 interface has been introduce to process an unconsolidated list of changes.
CDS-90557 Bug

CLONE - CmpIecVarAccess: Possible very rare crash when writing values during OnlineChange

Fixed
CDS-90549 Bug

CLONE - CmpWebServer: WebServerReadRequest() - Exception caused, if the number of bytes read is -1

Fixed [[GENERAL]]
For more details see CODESYS Security Advisory 2024-05, which is available on the CODESYS website:
https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=18604&token=d5e1e2820ee63077b875b3bb41014b1f102e88a3&download=
CDS-90548 Bug

CLONE - LibMan, Scripting: call of add_placeholder results in Namespace set to NOTIMPLEMENTEDBYDEVICE

Won't Fix [[GENERAL]]
This is a scripting issue and can only be fixed in the scripting package.
CDS-90531 Improvement

CLONE - CmpRetain: Setting needed to clear SRAM once at startup

Fixed [[GENERAL]]
- New setting to initialize SRAM at next bootup:
[CmpRetain]
Retain.SRAM.InitAtFirstBoot=1
=>Is set to 0 after first reboot!

- If bootproject is not an offline bootproject (a bootproject copied from another PLC), you have to specify a second setting, that the RETAINs must be initialized:
[CmpApp]
Bootproject.RetainMismatch.Init=1
CDS-90530 Bug

CLONE - RepositoryLocation.ini: Relative paths are not working after project open

Fixed
CDS-90529 Bug

CLONE - CmpIecTask C++ Runtime: IEC exception calling IecTaskGetWatchdogHitCount from IEC

Fixed
CDS-90476 Bug

CLONE - Runtime Toolkit Templates - Linux Makefile(s) incomplete and not working

Fixed
CDS-90475 Bug

CLONE - Resolve conflict crash codesys when use 3-way merge view

Fixed
CDS-90474 Improvement

CLONE - [PackageManagerCLI] Support signing packages with certificate thumbprint

Fixed [[GENERAL]]
PackageManagerCLI does now support the signing of packages with a certificate from the certificate store of the current user.
CDS-90473 Bug

CLONE - CmpApp: Timeout at OnlineChange is not handled correctly

Fixed
CDS-90472 Bug

CLONE - LibDoc: Malformed table error cannot be identified

Fixed
CDS-90357 Bug

CLONE - Security issues in CodeMeter versions before 8.10a

Duplicate [[GENERAL]]
Duplicates CDS-90742
CDS-90356 Improvement

CLONE - CmpLog: Support of dynamic logger string length

Fixed
CDS-90270 Bug

CLONE - Security issues in WibuCmNet versions before 8.10a

Fixed [[GENERAL]]
CODESYS uses now the version 8.10a of the WibuCmNet assembly.
CDS-90204 Improvement

CLONE - CmpIecVarAccess: Setting to limit the number of variable lists

Fixed
CDS-90203 Bug

CLONE - Import PLCOpenXML: Importing a function block with VAR_GENERIC leads to error

Fixed
CDS-90202 Bug

CLONE - VxWorks: High cpu load caused by SysEthernetGetPortConfigAndStatus()

Fixed [[GENERAL]]
Settings are now read only once at first call of SysEthernetGetPortConfigAndStatus()
CDS-90162 Bug

CLONE - CmpDevice session timouts for SIL3 protocol handler

Fixed
CDS-90161 Improvement

CLONE - Prepare Value Dialog: Insert a String without ' at the begin and end does not work

Fixed
CDS-90158 Bug

CLONE - Compiler: Internal error in CompilerPhase2_AfterTypification.CheckCallRecursionRecursive

Fixed Compiler Version >= 3.5.20.30
CDS-90126 Improvement

CLONE - SysMemVxWorks.c : Remove or adapt superflous log message

Fixed
CDS-90029 Improvement

CLONE - API or Hook needed to replace the CODESYS message "Selected target system is different from the connected device....."

Fixed [[GENERAL]]
Added a new Customization Hook with Section="OnlineManager" and Key="TargetMismatchHandler" and Type=Func<_3S.CoDeSys.Core.Online.TargetMismatchException2, bool>.
Instead of showing an error message, perform custom behavior for a TargetMismatchException. Return true, if the exception was handled. Return false, if the original error message should be displayed.
CDS-89968 Improvement

CLONE - RunTime Security: Add logs when there are errors with application Signing or Encryption

Fixed
CDS-89749 Improvement

CLONE - CmpIecTask: Add counters for lost cycles in Task_Desc structure

Fixed [[GENERAL]]
- New C- and IEC interface functions to get lost cycle counters:
RTS_RESULT CDECL IecTaskGetOmittedCycleCounters(RTS_HANDLE hIecTask, IecTaskOmittedCycleCounters *pOmittedCycleCounters);
- Worked only on targets with full CmpSchedule and the activated feature "IecTask.OmittedCycleInfos.xml"